Range hood CFM calculator

Enter your hood's width and how it mounts, and your burners if they are gas, to see the airflow to look for and whether makeup air may apply.

Checked Nov 20263 sources citedSee the working

This range hood size is a guide using HVI's rates and 2021 IRC section M1503.6, which states amend. South Carolina's text has no fuel appliance condition at all, so your building department and inspector decide. We read the code through state adoptions, not ICC's own copy. Compare HVI-certified airflow, as uncertified ratings can run high.

Where it goes

From the manual or the plate on the cooktop.

Is a fuel appliance inside the home, not direct-vent or power-vented?

A furnace, water heater or fireplace that uses indoor air and a natural draft. Section M1503.6 depends on this.

The code tests what a system is capable of, so turning it down does not count. Leave at 0 if you have none in mind.

Everything is worked out in this page. Nothing you type is sent.

Drawn to scale
0175350525700400 CFMThe range runs from HVI's minimum to its recommended rate for this hood.
Airflow to look for
400
CFM
Makeup air may be required
No
Makeup air rate, if required
0
CFM
HVI's recommended rate
250 CFM
HVI's minimum rate
100 CFM
The gas BTU rule
400 CFM

My project list

0 items

Add this, then whatever else the job needs. Everything you need to buy ends up here.

How we got 400 CFM

  1. HVI's recommended rate250 CFM
  2. The gas BTU rule400 CFM
  3. Makeup airNot flagged

Figures used

HVI's recommended airflow per foot of range, wall hood
100
HVI's minimum airflow per foot of range, wall hood
40
HVI's recommended airflow per foot of range, island hood
150
HVI's minimum airflow per foot of range, island hood
50
Airflow for each 10,000 BTU of gas cooktop
100

3 sources cited further down. Checked Nov 2026 by Anil, developer of this site.

Working

How to size a range hood

Start with the hood's width. The Home Ventilating Institute gives its rates per foot of range: 100 CFM per foot recommended against a wall, 40 at the minimum, and 150 and 50 over an island. Those rates are not tied to a fuel. HVI says that for professional-style cooktops you should follow the cooktop maker's advice.

For gas, you may also see a rule of 100 CFM per 10,000 BTU. This comes from a seller, World Coppersmith, and HVI does not state it, so treat it as a rough check. Add up your burners from the manual or the plate on the cooktop. The calculator shows both and looks for the larger one. Compare HVI-certified figures between hoods, since HVI says non-certified hoods often have inflated ratings, and recirculating hoods provide no real ventilation.

0125250375500400 CFMThe range runs from HVI's minimum to its recommended rate for this hood.
A 30 in wall hood over a 40,000 BTU gas cooktop, against HVI's range for that width. The BTU rule asks for more than HVI recommends.

Then look at makeup air, as it can change the price of the job. Section M1503.6 of the 2021 and 2024 IRC applies where a system can move over 400 CFM and a fuel-burning appliance that is neither direct-vent nor mechanical-draft sits inside the air barrier. Older editions had no such condition, and neither does South Carolina's text, so check what your area adopted. We read the code through state adoptions on UpCodes, since we could not open ICC's own site.

A worked example

Here is a 30 inch hood on a wall over a gas cooktop with 40,000 BTU across its burners. These lines come from the same formula the calculator above runs.

30 in wall hood, 40,000 BTU

  1. 30 ÷ 12 = 2.5 ft
  2. 2.5 × 100 = 250 CFM recommended
  3. 2.5 × 40 = 100 CFM minimum
  4. 40000 ÷ 10000 × 100 = 400 CFM on the BTU rule
  5. Look for about 400 CFM

That sits exactly at 400 CFM, and the code's test is "in excess of" 400, so this hood does not trigger it. Move up to 60,000 BTU, and the rule asks for 600 CFM. If a natural draft appliance is in the home, makeup air then applies at about that same rate, not just the part above 400. A remodel will price this in with the kitchen remodel calculator, and the bathroom fan calculator uses the same institute's method.

Range hood airflow by width

HVI's table prints the 30, 36 and 48 inch wall rows, and the others follow from its rates per foot. The 42 inch row comes to 350 CFM, which is why a seller's 420 CFM for that width does not match HVI's rate.

In CFM, from HVI's rates per linear foot.
HoodWall, recommendedWall, minimumIsland, recommendedIsland, minimum
24 in20080300100
30 in250100375125
36 in300120450150
42 in350140525175
48 in400160600200
60 in500200750250

Mistakes when choosing a hood

  • Buying the biggest one. A hood over 400 CFM can bring makeup air into the job, and it may not move more than you need.
  • Counting on the low setting. The code tests what a system is capable of exhausting, so a low setting does not avoid it.
  • Sizing only the excess. Makeup air under M1503.6 is at about the full exhaust rate. The figure for the excess came from a proposal and is not code.
  • Going ductless by default. HVI says nonducted hoods provide no actual ventilation. M1503.3 expects a smooth, airtight duct to the outdoors, with a listed ductless exception.
  • Forgetting the damper. M1503.6.2 asks for one that opens when the exhaust runs, by gravity or electrically.

Questions

How many CFM range hood do I need?

About 100 CFM per foot of range against a wall, and 150 CFM per foot over an island, by HVI. That is 250 CFM for a 30 inch wall hood. HVI's minimum rates are 40 and 50 per foot. With gas, check the BTU rule of thumb too.

How many CFM range hood for a gas stove?

About 100 CFM per 10,000 BTU, by a seller's rule of thumb that is not from HVI or a code. A 40,000 BTU cooktop comes to 400 CFM. HVI's rates are not fuel specific, and it says to follow the maker's advice on professional-style cooktops.

How many CFM for a range hood, 30 inch?

250 CFM recommended and 100 CFM minimum against a wall, by HVI's table. Over an island, its rates come to 375 and 125. A gas cooktop with many BTU may call for more on the rule of thumb, and the calculator shows that side by side.

How many CFM per BTU for a range hood?

About 1 CFM for each 100 BTU, as the rule of thumb is 100 CFM per 10,000 BTU. It comes from a seller and not from HVI, which states no rule by BTU. A 100,000 BTU stove comes to 1,000 CFM on this rule, which triggers the makeup air test.

What size range hood do I need for a 36 cooktop?

300 CFM recommended and 120 CFM minimum for a 36 inch hood on a wall, by HVI. Over an island, its rates come to 450 and 150. We have no primary source on how much wider than the cooktop a hood should be, so check the maker's guide.

What are the makeup air requirements for a range hood?

Makeup air at about the exhaust rate if the system can move over 400 CFM and a natural draft fuel appliance sits inside the air barrier, by IRC M1503.6. States differ, as South Carolina has no fuel condition. The test is what it can move, even turned down.

How much does makeup air for a range hood cost?

We have no reliable figure, so get a quote. A system can be passive or mechanical under M1503.6, and M1503.6.2 asks for a damper that opens when the exhaust runs. Ask an HVAC contractor to price the size your hood's capacity calls for.

When do I need a professional?

When a hood's capacity is over 400 CFM in a home with a natural draft furnace, water heater or fireplace, or when you need a new duct through a wall or a roof. An HVAC contractor can size the makeup air, and your inspector decides what applies.

This range hood size is a guide using HVI's rates and 2021 IRC section M1503.6, which states amend. South Carolina's text has no fuel appliance condition at all, so your building department and inspector decide. We read the code through state adoptions, not ICC's own copy. Compare HVI-certified airflow, as uncertified ratings can run high.

Sources and review

Checked in November 2026. Spotted a wrong number? Report it and it goes in the corrections log.

How this is calculated

Every figure below is read from the code that produces the answer, so what is written here is what the calculator ran. The constants were last checked against their sources in November 2026.

The arithmetic

HVI's rate

CFM = Hood width in feet × Rate per foot

Rate per foot
100 recommended on a wall, and 150 over an island

Worked through: 2.5 × 100 = 250

Gas rule of thumb

CFM = Total BTU ÷ 10,000 × 100

Total BTU
All burners added up

Worked through: 40000 ÷ 10000 × 100 = 400

The constants, and where they come from

WALL_RECOMMENDED_CFM_PER_FOOT

Published figure

HVI's recommended airflow per foot of range, wall hood

100

Applies to: Hoods in homes. HVI says to follow the maker's advice on professional-style cooktops

Source: How much ventilation do I need?, Home Ventilating Institute, no date on the page, read 2026-11.

Also from: IAQ position paper, Home Ventilating Institute, published 2009-10, read 2026-11.

HVI's width table gives 250 CFM at 30 inches, 300 at 36 and 400 at 48. These rates are not fuel specific.

WALL_MINIMUM_CFM_PER_FOOT

Published figure

HVI's minimum airflow per foot of range, wall hood

40

Applies to: Hoods in homes. HVI says to follow the maker's advice on professional-style cooktops

Source: How much ventilation do I need?, Home Ventilating Institute, no date on the page, read 2026-11.

HVI's width table gives 100 CFM at 30 inches, 120 at 36 and 160 at 48, which match this rate. Its 2009 position paper gives the same 40.

ISLAND_RECOMMENDED_CFM_PER_FOOT

Published figure

HVI's recommended airflow per foot of range, island hood

150

Applies to: Hoods in homes. HVI says to follow the maker's advice on professional-style cooktops

Source: How much ventilation do I need?, Home Ventilating Institute, no date on the page, read 2026-11.

HVI says to multiply the rate by 1.5 for hoods over islands, and its table gives 150. Its 2009 position paper gives the same figure.

ISLAND_MINIMUM_CFM_PER_FOOT

Published range, narrowed

HVI's minimum airflow per foot of range, island hood

50

Applies to: Hoods in homes. HVI says to follow the maker's advice on professional-style cooktops

Source: How much ventilation do I need?, Home Ventilating Institute, no date on the page, read 2026-11.

HVI's table gives 50, though multiplying its wall minimum of 40 by 1.5 would give 60. The table and its sentence disagree here, and we use the table.

CFM_PER_10000_BTU

Modelled from published data

Airflow for each 10,000 BTU of gas cooktop

100

Applies to: A seller's rule of thumb, which is not from HVI or any code

Source: How much CFM does a range hood need?, World Coppersmith, no date on the page, read 2026-11.

World Coppersmith gives this rule, and says a 100,000 BTU stove needs 1,000 CFM. HVI does not state a rule by BTU. We use the larger of this and HVI's rate.

CODE_MINIMUM_CFM

Published figure

IRC minimum for a kitchen fan run intermittently

100

Applies to: The model IRC, read through state adoptions, which may be amended

Source: IRC 2021 chapter 15, exhaust systems, International Code Council, via UpCodes, published 2021, read 2026-11. This source is about 5 years old, and it is the one the figure rests on.

Also from: IRC 2024 chapter 15, exhaust systems, International Code Council, via UpCodes, published 2024, read 2026-11.

Table M1505.4.4 in the 2021 IRC and Table M1505.5 in 2024. The code also allows 25 cfm of continuous exhaust, which a hood rarely is.

MAKEUP_AIR_THRESHOLD_CFM

Published figure

Exhaust above which makeup air may be required

400

Applies to: The model IRC, read through state adoptions, which may be amended

Source: IRC 2021 chapter 15, exhaust systems, International Code Council, via UpCodes, published 2021, read 2026-11. This source is about 5 years old, and it is the one the figure rests on.

Also from: IRC 2024 chapter 15, exhaust systems, International Code Council, via UpCodes, published 2024, read 2026-11.

Also from: IRC M1503.4 proposal, International Code Council, published 2014-03, read 2026-11.

Section M1503.6 applies only with a fuel-burning appliance that is neither direct-vent nor mechanical-draft inside the air barrier. Older editions and some states have no such condition.

INCHES_PER_FOOT

Definitional

Inches in one foot

12

Applies to: Definitional, everywhere

True by definition, so there is nothing to cite. The derivation is below.

Twelve inches make a foot by definition, so a hood's width in inches is divided by 12 to apply a rate per linear foot.

What the labels mean

Published figure:
taken directly from the source named beside it.
Published range, narrowed:
a source publishes a range and this calculator uses a representative value from it.
Modelled from published data:
derived rather than measured, calibrated against the source named beside it.
Definitional:
true by definition, like the number of inches in a foot, so there is nothing to cite.

If a figure here looks wrong, it may be. Tell us what you found and we will check it against the source and publish a correction if it needs one. How constants are chosen and how often they are reviewed is set out in our methodology.

How to use the range hood CFM calculator

  1. 1

    Choose the hood's width

  2. 2

    Say if it is on a wall or over an island

  3. 3

    Say if the cooktop is gas, and add up its burners

  4. 4

    Say if the home has a natural draft fuel appliance

  5. 5

    Compare HVI-certified ratings, and ask your building department about makeup air

What this calculator assumes

Every estimate here rests on the assumptions below. Where your job differs from one of them, the figure will differ too.

  • The target is the largest of HVI's recommended rate, the BTU rule and the code minimum
  • The gas BTU rule is a seller's rule of thumb, not from HVI or any code
  • Makeup air is flagged above 400 CFM unless you say there is no such appliance
  • Duct length is not counted, since we found no primary figure for it

Pro tips

  • Compare HVI-certified CFM between hoods
  • Discharge outdoors through a smooth, airtight duct
  • Ask your building department which edition it has adopted